Guide prices in Lancashire
Vent swap
Like-for-like certified vent and actuator, connected to the existing controls and commissioned by a smoke-control specialist
Vent with new controls
Vent plus new control panel and detection, commissioned by a smoke-control specialist
Multiple vents
Several stairwells or larger systems, priced from a survey
Guide ranges for supply & fit; controls and commissioning by a smoke-control specialist. Your price is fixed in a written quote after we have seen photos or surveyed. Scaffold, access towers or a crane are priced separately if the job needs them, and building control fees, where a job needs them, are shown as their own line.
Towns we list in Lancashire
Fitting across Lancashire means planning routes, access and lifting as well as the roof itself. Narrow lanes, shared driveways and town-centre parking restrictions all affect how a large unit is delivered and raised to roof level. We ask about these early so the quote reflects them. That approach is the same everywhere we work in England, from single domestic jobs to multi-unit commercial sites.
- Smoke vents (AOV) in Accrington
- Smoke vents (AOV) in Blackburn
- Smoke vents (AOV) in Blackpool
- Smoke vents (AOV) in Burnley
- Smoke vents (AOV) in Chorley
- Smoke vents (AOV) in Colne
- Smoke vents (AOV) in Darwen
- Smoke vents (AOV) in Fleetwood
- Smoke vents (AOV) in Haslingden
- Smoke vents (AOV) in Heysham
- Smoke vents (AOV) in Lancaster
- Smoke vents (AOV) in Leyland
- Smoke vents (AOV) in Lytham St Annes
- Smoke vents (AOV) in Morecambe
- Smoke vents (AOV) in Nelson
- Smoke vents (AOV) in Ormskirk
- Smoke vents (AOV) in Poulton-le-Fylde
- Smoke vents (AOV) in Preston
- Smoke vents (AOV) in Rawtenstall
- Smoke vents (AOV) in Skelmersdale
- Smoke vents (AOV) in Thornton-Cleveleys
Included in the work
- Commissioning and sign-off carried out by the specialist before handover
- New vent fitted, sealed and weathered into the roof
- Controls, detection and wiring handled by the smoke-control specialist
- Certified as a system — We only fit smoke vents that are certified to BS EN 12101-2.
- Controls and backup power — We confirm the controls, detection and backup power are being dealt with by a specialist.
Rules that apply in England
In England, smoke vents for common stairs must be certified to BS EN 12101-2, provide the free area the fire strategy requires (Approved Document B calls for at least 1 m² at the top of a common stair), and have backup power. Smoke vents have their own energy limit, commonly 3.5 W/m²K. Controls and commissioning are handled by a smoke-control specialist, and building control is involved where the system changes.
Common questions in Lancashire
Can you remove and dispose of the old rooflight?
Yes. Taking out the old unit is part of any replacement job, and it leaves with the rest of the waste unless you ask to keep it. Old domes, glass and frames go through proper waste routes. If removal turns up a rotten kerb or damaged decking, we show you what we have found and agree the repair with you before going any further.
Who is responsible for the smoke-control system?
The building's responsible person, duty holder or managing agent, depending on the nation, is responsible for keeping fire safety systems working. Our part is the rooflight and roof work; the controls, detection and commissioning are handled by a smoke-control specialist, and the quote says who does what.
Do commercial rooflights need planning permission?
Like-for-like replacements on commercial buildings rarely need planning permission. New or larger rooflights on non-domestic buildings and blocks of flats usually need checking with the planning authority, because householder permitted development rights don't apply. We tell you what we know about your building and point you to the right team.