An upstand is the timber kerb a flat-roof rooflight sits on, and most fitting problems start there. Each maker sets the kerb size, the minimum height above the finished roof and whether the kerb should be level or built to a fall. We build upstands in Wallasey to those figures for the rooflight you have chosen, insulate the faces that need it and dress the roof membrane up and over so the kerb is weathertight. Every job is quoted in writing first.

Guide price from £245 · Labour and materials, rooflight not included

Wallasey guide prices

Timber upstand

£245 – £445including VAT at 20%

Treated timber kerb built square and level to the maker's size

Insulated upstand

£445 – £845including VAT at 20%

Kerb with insulation and the roof membrane turned up and dressed

Large or with trimming

£845 – £1,445including VAT at 20%

Bigger kerbs or where joists need trimming first

Guide ranges for labour and materials, rooflight not included. Your price is fixed in a written quote after we have seen photos or surveyed. Scaffold, access towers or a crane are priced separately if the job needs them, and building control fees, where a job needs them, are shown as their own line.

Covering CH45 and neighbouring districts

Covering Wallasey means covering the people who live and work there, not a single postcode. We take on domestic and commercial jobs in CH45, CH44 and CH46, and are happy to quote further out in Moreton and Birkenhead. If your address sits between towns, tell us and we will confirm whether it falls in our normal area or needs travel set out separately on the quote.

On the day, we cover

  • Treated timber frame fixed down to the deck and joists
  • Kerb sized from the maker's drawing, internal and external dimensions both checked
  • Diagonals measured so the kerb is square before anything sits on it
  • Energy limit for site-built kerbs — We insulate upstands to meet the limit for site-built upstands, which is 0.35 W/m²K in England and Wales.
  • Fall built in or level — We confirm whether your rooflight needs the kerb to provide a fall or should sit level.

What happens on the day

The fitters measure twice before cutting: the opening, the rooflight's kerb size and the finished roof level. The kerb is built, packed level or to the maker's fall, insulated and weathered into the roof covering. You are left with an upstand ready for the rooflight, and a note of the sizes it was built to.

Regulations for Wallasey properties

In England, a new rooflight opening generally needs building regulations approval because the roof structure is altered and the glazing must meet energy rules: 2.2 W/m²K for a rooflight in an existing home, or 1.4 W/m²K (or WER Band B) for a roof window. Planning is often not needed on a house: permitted development covers rooflights that stand no more than 0.15 m proud of the roof slope and sit below the highest part of the roof. Flats, listed buildings and areas with an Article 4 direction are different, so we check your address first.

Before you get in touch

Each detail you send takes a question off our list. Photos inside and out show the opening and the ceiling. Rough measurements tell us the unit size. The roof covering tells us how it will be sealed in. Access notes tell us whether a tower or scaffold is needed. A product link, if you have one, lets us check it against the opening. Your postcode, CH45 or nearby, confirms travel.

Common questions in Wallasey

What is included in the price?

The written quote lists it line by line. Typically that covers fitting labour, fixings, sealants, membrane or flashing materials, any upstand work, internal finishing if agreed, and taking away the waste. For supply and fit, the unit itself is included too. Scaffold, lifting gear and any third-party fees, where needed, are shown separately so you can see what each part of the job costs.

Does a rooflight need building regulations approval?

A new opening usually needs building regulations approval. A replacement is a controlled fitting: it must be self-certified by an installer registered with a competent person scheme or notified to building control. We are not registered with a scheme, so replacements we fit are notified to building control with a building notice, and the council's fee is shown on your quote.

Do I need planning permission for a rooflight in Wallasey?

Often not. Many rooflights fall under permitted development, provided they do not project beyond the national limit and meet the other conditions that apply in England. Conservation areas, listed buildings and some flats are different and may need consent. Because the rules depend on the property, we confirm what is likely to apply at your address and point you to the planning authority where an application is needed.