Fit-onlySupply & fitReplacementsTrade fitting
Fitting teams across England, Wales, Scotland & NI · Call 0800 088 6248
RooflightInstallers.co.uk
Worthing · BN11 · West Sussex

Smoke vent rooflight installation in Worthing

A rooflight is not finished when the roof is watertight. The inside matters too: the reveal or lining around the opening, the plaster, the trim where it meets the ceiling. Some installers leave that for somebody else. When we quote for smoke vent rooflight installation in Worthing, internal finishing is listed so you can see whether it is included or left for your decorator. That way a smoke vent rooflight looks right from the room below as well as from outside. We cover Worthing and properties throughout West Sussex.

Guide price from £3,595 · Supply & fit; controls and commissioning by a smoke-control specialist

Guide prices in Worthing

Vent swap

£3,595 – £6,595including VAT at 20%

Like-for-like certified vent and actuator, connected to the existing controls and commissioned by a smoke-control specialist

Vent with new controls

£5,745 – £9,595including VAT at 20%

Vent plus new control panel and detection, commissioned by a smoke-control specialist

Multiple vents

£9,595 – £17,995including VAT at 20%

Several stairwells or larger systems, priced from a survey

Guide ranges for supply & fit; controls and commissioning by a smoke-control specialist. Your price is fixed in a written quote after we have seen photos or surveyed. Scaffold, access towers or a crane are priced separately if the job needs them, and building control fees, where a job needs them, are shown as their own line.

Is your address covered?

Distance is rarely the deciding factor. A roof in Lancing, 2 miles from Worthing, gets the same survey, the same written quote and the same fitting process as one in BN11, BN14 and BN13. What changes the price is the job itself: size of unit, roof type, access and lifting. Shoreham-by-Sea, around 5 miles out, is treated the same way.

Included in the work

  • Old vent removed with the stairwell kept protected below
  • Existing vent, actuator and upstand surveyed with the specialist
  • Certified vent and actuator matched to the opening and controls
  • Controls and backup power — We confirm the controls, detection and backup power are being dealt with by a specialist.
  • Certified as a system — We only fit smoke vents that are certified to BS EN 12101-2.

Fitting your smoke vent rooflight, step by step

Arrive and agree the plan. Sheet the floor and furniture. Set up the ladder, tower or scaffold. Check the opening, the upstand or flashing, and the unit against the paperwork. Fix and pack a smoke vent rooflight level. Seal it into the roof. Line the reveal or fit the ceiling trim. Clean the glass, clear the waste, and talk you through it. That is the shape of most fitting days, and for this type of job it usually takes one to two days per vent.

Planning and building rules in England

In England, smoke vents for common stairs must be certified to BS EN 12101-2, provide the free area the fire strategy requires (Approved Document B calls for at least 1 m² at the top of a common stair), and have backup power. Smoke vents have their own energy limit, commonly 3.5 W/m²K. Controls and commissioning are handled by a smoke-control specialist, and building control is involved where the system changes.

Details that speed up your quote

Each detail you send takes a question off our list. Photos inside and out show the opening and the ceiling. Rough measurements tell us the unit size. The roof covering tells us how it will be sealed in. Access notes tell us whether a tower or scaffold is needed. A product link, if you have one, lets us check it against the opening. Your postcode, BN11 or nearby, confirms travel.

Common questions in Worthing

Do you cover Worthing?

Yes. Fitters travel to addresses in Worthing and the surrounding districts, including BN11. We do not run an office there; the survey and the fitting happen at your property. A few island and remote postcodes are covered by arrangement; if yours is one, we confirm travel and dates before quoting.

How long does fitting take?

Fitting a smoke vent rooflight into an existing, correctly sized opening is often a day's work. New openings take longer, because joists or rafters need trimming, an upstand or flashing has to be built or fitted, and the inside needs finishing. Large units that need lifting gear, and days lost to rain, can stretch things further. Your written quote gives a realistic estimate for your roof.

How does payment work?

Payment terms are set out on your written quote before you accept it. Depending on the job, that may mean a deposit, stage payments for larger work, or payment on completion. The contract is with S&K Property Investments and Improvement Ltd, part of the S&K Group. Nothing is added without your agreement: if something unexpected comes up, we discuss it and agree any change before carrying on.

Planning a smoke vent rooflight in Worthing? Tell us about the roof and we will come back with a clear price in writing.

Rear extension at dusk with lit rooflights and a roof lantern
Ready when you are

Smoke vents (AOV) in Worthing

Send photos and rough sizes, or ask for a survey for install work. One fixed written price before anything starts.

CallGet a quote