Guide prices in Buckinghamshire
Vent swap
Like-for-like certified vent and actuator, connected to the existing controls and commissioned by a smoke-control specialist
Vent with new controls
Vent plus new control panel and detection, commissioned by a smoke-control specialist
Multiple vents
Several stairwells or larger systems, priced from a survey
Guide ranges for supply & fit; controls and commissioning by a smoke-control specialist. Your price is fixed in a written quote after we have seen photos or surveyed. Scaffold, access towers or a crane are priced separately if the job needs them, and building control fees, where a job needs them, are shown as their own line.
Towns we list in Buckinghamshire
We work right across England, and Buckinghamshire is covered on the same footing as everywhere else. There is no showroom or depot to visit. The survey happens at your property or, for fit-only jobs, from your photos. If your address is remote or reached by ferry, tell us early and we will confirm what arrangement is needed before quoting.
- Smoke vents (AOV) in Amersham
- Smoke vents (AOV) in Aylesbury
- Smoke vents (AOV) in Bletchley
- Smoke vents (AOV) in Chalfont St Peter
- Smoke vents (AOV) in Chesham
- Smoke vents (AOV) in Gerrards Cross
- Smoke vents (AOV) in High Wycombe
- Smoke vents (AOV) in Marlow
- Smoke vents (AOV) in Milton Keynes
- Smoke vents (AOV) in Newport Pagnell
Included in the work
- Controls, detection and wiring handled by the smoke-control specialist
- Old vent removed with the stairwell kept protected below
- Certified vent and actuator matched to the opening and controls
- Certified as a system — We only fit smoke vents that are certified to BS EN 12101-2.
- Fire rules near escape routes — We check the roof around the vent for fire rules that affect it.
Rules that apply in England
A replacement smoke vent in England has to keep the free area and performance the building's fire strategy relies on, using a vent certified to BS EN 12101-2 with its actuator and backup power. We fit the vent and do the roof work; a smoke-control specialist connects and commissions the controls, and we confirm whether building control needs to be notified.
Common questions in Buckinghamshire
What if my roof opening is the wrong size for the smoke vent rooflight?
We find out before the fitting day, not on it. If the opening is slightly out, it can usually be adjusted by trimming or by packing out the upstand. If it is a long way off, the choice is between altering the opening and changing the unit. Bear in mind that rooflights are often sold by builder's opening size rather than external size, so check which one your measurement refers to.
Do commercial rooflights need planning permission?
Like-for-like replacements on commercial buildings rarely need planning permission. New or larger rooflights on non-domestic buildings and blocks of flats usually need checking with the planning authority, because householder permitted development rights don't apply. We tell you what we know about your building and point you to the right team.
Can you fit a rooflight in winter or when it is raining?
Yes, within limits. Cold is less of a problem than wet, because membranes, primers and sealants need a dry surface to bond. We plan fitting days around the forecast and may move a date if heavy rain is due. If the roof has to be opened up, it is not left overnight without a temporary weather seal, so the room below stays dry while the work is finished.