Fit-onlySupply & fitReplacementsTrade fitting
Fitting teams across England, Wales, Scotland & NI · Call 0800 088 6248
RooflightInstallers.co.uk
High Wycombe · HP11 · Buckinghamshire

Rooflight replacement in High Wycombe

A rooflight is not finished when the roof is watertight. The inside matters too: the reveal or lining around the opening, the plaster, the trim where it meets the ceiling. Some installers leave that for somebody else. When we quote for rooflight replacement in High Wycombe, internal finishing is listed so you can see whether it is included or left for your decorator. That way a replacement rooflight looks right from the room below as well as from outside. We cover High Wycombe and properties throughout Buckinghamshire.

Guide price from £1,095 · Supply & fit; building control notice fee extra in England and Wales

Guide prices

Like-for-like swap

£1,095 – £1,695including VAT at 20%

Old dome or unit removed and disposed of, new glass rooflight fitted to the existing sound kerb

New upstand and swap

£1,695 – £2,645including VAT at 20%

Old kerb taken off, new insulated upstand built, roof covering made good, new unit fitted

Opening or large unit

£2,645 – £4,545including VAT at 20%

Electric or larger replacement, including making good inside

Guide ranges for supply & fit; building control notice fee extra in England and Wales. Your price is fixed in a written quote after we have seen photos or surveyed. Scaffold, access towers or a crane are priced separately if the job needs them, and building control fees, where a job needs them, are shown as their own line.

Areas around High Wycombe we cover

Covering High Wycombe means covering the people who live and work there, not a single postcode. We take on domestic and commercial jobs in HP11, HP13 and HP12, and are happy to quote further out in Marlow and Amersham. If your address sits between towns, tell us and we will confirm whether it falls in our normal area or needs travel set out separately on the quote.

Buying your own, or letting us supply

Supply and fit tends to suit people who would rather not pick a unit from a catalogue. We look at the roof, the opening and how you use the room, then put a replacement rooflight on the quote that fits all three. Fit-only suits people who already know what they want, or have one on site. We are happy with either. The difference is who stands behind what: on fit-only, the maker or retailer covers the product, and our workmanship guarantee covers the installation.

On the day, we cover

  • Kerb inspected for rot, height, level and fall once the old unit is off
  • Internal reveal made good where the old trim or plaster was damaged
  • Roof membrane repaired and turned up where it meets the kerb
  • Energy rules for the new unit — We make sure the replacement meets the current energy limit, not just the old unit's performance.
  • Leaks that are not the rooflight — We look at the roof around the unit before blaming the rooflight.

A typical installation day

Arrive and agree the plan. Sheet the floor and furniture. Set up the ladder, tower or scaffold. Check the opening, the upstand or flashing, and the unit against the paperwork. Fix and pack a replacement rooflight level. Seal it into the roof. Line the reveal or fit the ceiling trim. Clean the glass, clear the waste, and talk you through it. That is the shape of most fitting days, and for this type of job it usually takes one day.

Do you need permission in High Wycombe?

England's rules in short: permitted development usually covers a rooflight on a house roof provided it doesn't stick out more than 0.15 m or rise above the ridge, though a listed building always needs consent and some streets have Article 4 directions. Building regulations apply to new openings, and replacements go through building control; as we are not registered with a competent person scheme, we use a building notice and show the fee on the quote. The energy limit for rooflights in existing homes is 2.2 W/m²K, and the 2026 Approved Document L, in force from 24 March 2027, keeps that figure.

Getting a price from photos

For fit-only work, the product details matter most: the link, the spec sheet, or a photo of the label on the box. Alongside that, send pictures of the roof and the ceiling below, approximate opening sizes, the type of roof covering, and how someone would get onto the roof. For supply and fit, the same photos and sizes do the job. Finish with your postcode, such as HP11.

Common questions in High Wycombe

What upstand height and roof pitch does replacement rooflight fitting need?

It depends on the product. Manufacturers usually specify a minimum upstand height above the finished roof surface, and a minimum pitch on the glass so rain runs off. We follow the maker's figures for your unit rather than a rule of thumb. If your existing kerb or roof falls short, we explain the options, such as raising the upstand or choosing a unit with built-in pitch.

Can you replace an old dome without redoing the whole roof?

Usually, yes. If the existing kerb is sound, level and tall enough, a new unit can often sit on it with a fresh seal to the roof covering. If the kerb is rotten or too low, we rebuild it and patch the covering around it rather than stripping the whole roof. This is checked at the survey and included in the written quote, so you know the full scope first.

Can you remove and dispose of the old rooflight?

Yes. Taking out the old unit is part of any replacement job, and it leaves with the rest of the waste unless you ask to keep it. Old domes, glass and frames go through proper waste routes. If removal turns up a rotten kerb or damaged decking, we show you what we have found and agree the repair with you before going any further.

Send a few photos and your HP11 postcode, and we will put together a written quote for the job.

Rear extension at dusk with lit rooflights and a roof lantern
Ready when you are

Replacements in High Wycombe

Send photos and rough sizes, or ask for a survey for install work. One fixed written price before anything starts.

CallGet a quote