Water dripping under a rooflight does not always mean the rooflight itself has failed. It might be the sealant, the flashing, the upstand, or water sitting on the roof against the kerb. That is why a repair in Twickenham starts with finding the cause rather than reaching for a sealant gun. The investigation visit is charged, and we confirm that price before you book it. Once we know what is wrong, you get a written quote for the repair, or honest advice that replacement makes more sense.

Guide price from £145 · Charged visit, then repair priced before any work

What the job costs in Twickenham

Diagnostic visit

£145 – £195including VAT at 20%

Roof and inside inspected, cause found, written repair price

Reseal and re-flash

£295 – £645including VAT at 20%

Failed sealant and flashing taken out, joints cleaned, resealed and taped

Upstand or membrane repair

£645 – £1,445including VAT at 20%

Rotten kerb section or roof membrane at the upstand repaired

Guide ranges. The first visit is charged and priced before booking; any repair is priced in writing before work starts. Scaffold, access towers or a crane are priced separately if the job needs them, and building control fees, where a job needs them, are shown as their own line.

Is your address covered?

Distance is rarely the deciding factor. A roof in Richmond, 1 mile from Twickenham, gets the same survey, the same written quote and the same fitting process as one in TW1, TW2 and TW10. What changes the price is the job itself: size of unit, roof type, access and lifting. Hounslow, around 2 miles out, is treated the same way.

What the job includes

  • Controlled water test where it helps pin down the entry point
  • Inside check of stains, frame drainage channels and the reveal
  • Lifted flashing or tape removed and renewed
  • Upstand height and condition — We measure the kerb and probe the timber for softness.
  • Leak or condensation — We work out whether the water is coming from outside or forming inside on cold glass.

How a repair visit goes

Expect the visit to be mostly looking and testing. Dust sheets go down below the rooflight. The fitter checks seals and glass from inside, then gets up on the roof by ladder or tower. Minor jobs such as clearing a blocked drainage channel can often be dealt with there and then. Bigger work, like new flashing or a replacement sealed unit, is measured up and priced in writing afterwards.

Planning, building control and Twickenham

Two sets of rules matter in England. Planning: a rooflight on a house is normally permitted development if it projects no more than 0.15 m and stays below the highest part of the roof, but flats, listed buildings and Article 4 areas need checking. Building regulations: new openings need approval for the structure and energy performance, and a replacement is a controlled fitting. We are not registered with a competent person scheme, so we notify replacements to building control with a building notice and put the council's fee on the quote.

What to send us

Photos help us price the visit. Send one of the stain or drip inside, one of the rooflight from outside if you can reach a safe viewpoint, and a note of when it leaks: in heavy rain, in wind, or all the time. Add the postcode, TW1 or similar, and how the roof is reached.

Common questions in Twickenham

Why is my rooflight leaking?

The usual causes are sealant that has cracked or pulled away, flashing or membrane that has perished at the edges, condensation channels blocked with dirt, water ponding against the kerb, or a seal failing on the glass unit. Sometimes the water is coming in elsewhere and running along to the rooflight. A diagnostic visit finds the real source before anyone starts applying sealant.

Will resealing fix my leaking rooflight?

Sometimes. If the sealant has simply aged and the flashing, upstand and glass are sound, a careful reseal on a dry day can solve it. If the real problem is ponding water, a low upstand or a perished membrane, fresh sealant will only hide it for a while. We tell you which one you are dealing with before recommending any work, and quote the proper fix in writing.

Can you replace just the misted glass?

Often, yes. Misting between the panes means the sealed unit has failed, but the frame around it may be perfectly sound. Where the maker's design allows the glass to be changed, we measure the unit and fit a replacement, which costs less than a whole new rooflight. Where it does not, or the frame is also worn out, we explain why replacement is the better option.

Send photos of the problem in Twickenham and we will price the visit before you book it.