Pitched roof window installation in Aston

A rooflight is not finished when the roof is watertight. The inside matters too: the reveal or lining around the opening, the plaster, the trim where it meets the ceiling. Some installers leave that for somebody else. When we quote for pitched roof window installation in Aston, internal finishing is listed so you can see whether it is included or left for your decorator. That way a pitched roof window looks right from the room below as well as from outside. We cover Aston and properties throughout West Midlands.

Guide price from £845 · Supply & fit

What the job costs in Aston

Standard window

£845 – £1,395including VAT at 20%

Centre-pivot roof window with flashing kit, tiles cut and refitted, inner lining

Larger or top-hung

£1,395 – £2,045including VAT at 20%

Bigger or top-hung windows, or two in the same roof

Electric or pair

£2,045 – £3,095including VAT at 20%

Electric or solar windows, or a matched pair with blinds

Guide ranges for supply & fit. Your price is fixed in a written quote after we have seen photos or surveyed. Scaffold, access towers or a crane are priced separately if the job needs them, and building control fees, where a job needs them, are shown as their own line.

Covering B6 and neighbouring districts

Looking at a property near Aston but not quite in it? We work across B6, B7 and B19 and outwards to Birmingham, Smethwick and Acocks Green. Give us the full postcode when you get in touch, because access, parking and the route for a large unit all depend on the exact street. Those details shape the quote for any job around Aston.

Fit-only or supply and fit

A damaged delivery is a frequent snag on fit-only work. Before the day, unpack a pitched roof window, photograph it, and tell the seller about any cracks or scuffs, because claims are much easier made early. We will also ask for the model or a link, so we can read the maker's instructions and check the opening size and the flashing kit it expects. If everything lines up, we fit it. If not, we explain what needs changing first.

What the job includes

  • Rafters trimmed where the window is wider than the gap between them
  • Insulation collar and vapour layer fitted to stop a cold edge
  • Inside lining fitted and left ready for decoration
  • Scaffold or not — We look at the roof height and the window position to see whether scaffolding is needed.
  • Head height and view — We think about how the window will be used from inside before fixing its height.

A typical installation day

On the day, you need to be in at the start and at the end. In between, the fitters get on with it. They will want the room below cleared where possible, a parking spot if you have one, and somewhere to set the unit down safely. After checking the opening and the upstand or flashing, they fix a pitched roof window, seal it and finish the inside. Packaging and any old unit leave with them unless the quote says otherwise.

Planning, building control and Aston

Replacing a rooflight in an English home is a controlled fitting: it has to be self-certified by a scheme-registered installer or notified to building control. We are not registered with a competent person scheme, so replacements we fit are notified with a building notice, and the new unit has to meet current energy limits. Adding a new one usually means a building regulations application, because joists or rafters are trimmed. On the planning side, most house rooflights are permitted development if they project 0.15 m or less; on a side slope the glass must be obscured and fixed unless the opening part is over 1.7 m above the floor.

What to send for a quick quote

A fast quote needs five things: a photo of the roof from outside, one from the room below, rough sizes of the opening or the space, the roof covering (felt, single-ply, fibreglass, tiles, slate or metal), and a note on access. If you have already bought the unit, add the product link or spec sheet. And give us the postcode, B6 or a neighbouring district.

Common questions in Aston

Will my new pitched roof window leak?

A correctly fitted unit should not. Leaks usually trace back to the detail around the frame: an upstand that is too low, a membrane or flashing that is not dressed properly, sealant applied to a damp surface, or water ponding against the kerb. We fit to the maker's instructions and check each of those points. The fitting carries a written workmanship guarantee, with its terms set out on your quote.

What if my roof opening is the wrong size for the pitched roof window?

We find out before the fitting day, not on it. If the opening is slightly out, it can usually be adjusted by trimming or by packing out the upstand. If it is a long way off, the choice is between altering the opening and changing the unit. Bear in mind that rooflights are often sold by builder's opening size rather than external size, so check which one your measurement refers to.

How does payment work?

Payment terms are set out on your written quote before you accept it. Depending on the job, that may mean a deposit, stage payments for larger work, or payment on completion. The contract is with S&K Property Investments and Improvement Ltd, part of the S&K Group. Nothing is added without your agreement: if something unexpected comes up, we discuss it and agree any change before carrying on.

Get in touch with the details of your Aston property and we will explain what the job involves and what it costs.

Rear extension at dusk with lit rooflights and a roof lantern
Ready when you are

Roof windows in Aston

Send photos and rough sizes, or ask for a survey for install work. One fixed written price before anything starts.

CallGet a quote