Roof lantern installation in Eccles

Glass is heavy, and bigger units get heavy fast. Fitting a roof lantern in Eccles means planning how it travels from the delivery vehicle to the roof without chipping an edge or straining a back. Smaller units go up by hand with two fitters. Larger ones may need a hoist, a scaffold loading bay or a crane, and we tell you at quote stage if that applies. Once it is up, the fitting follows the maker's sequence: seat, fix, seal, finish. We take on work like this across Greater Manchester.

Guide price from £3,095 · Supply & fit

Eccles guide prices

About 1 × 2 m

£3,095 – £4,545including VAT at 20%

Aluminium lantern, double glazed, fitted and glazed on a ready upstand

About 1.5 × 3 m

£4,545 – £7,195including VAT at 20%

Mid-size lantern, solar-control glass options

2 × 4 m and over

£7,195 – £11,395including VAT at 20%

Large lanterns, lifting gear on the day

Guide ranges for supply & fit. Your price is fixed in a written quote after we have seen photos or surveyed. Scaffold, access towers or a crane are priced separately if the job needs them, and building control fees, where a job needs them, are shown as their own line.

Coverage in and around Eccles

Distance is rarely the deciding factor. A roof in Swinton, 1 mile from Eccles, gets the same survey, the same written quote and the same fitting process as one in M30, M17 and M6. What changes the price is the job itself: size of unit, roof type, access and lifting. Salford, around 2 miles out, is treated the same way.

Fit-only or supply and fit

Your unit or ours, the fitting standard is the same. For supply and fit we choose a roof lantern to suit the roof and price it with the installation. For fit-only we work with what you have, after confirming it arrived undamaged, that it matches the builder's opening, and that the upstand will sit at the height the maker asks for. Report any transit damage to the seller, as the product cover is theirs and the maker's. Our written guarantee applies to the fitting itself.

What we do on the day

  • Glass cleaned and packaging cleared from the roof
  • Frame assembled on the kerb in the maker's set order
  • Glass lifted and laid into the frame by hand or with gear
  • Lanterns and planning — We check whether your lantern can go in without a planning application.
  • Upstand size and tolerance — We check the kerb against the lantern maker's figures before the kit is opened.

Fitting your roof lantern, step by step

Protection comes before tools. Floors, furniture and stairs get covered, and the ceiling below the opening is sheeted to catch dust. Up top, the fitters confirm the opening is square and the upstand or flashing suits what the maker specifies. Fixing follows, then weather-sealing into the membrane, felt or tiles. Only once the roof is tight do they turn to the internal reveal. Time on site for a roof lantern: one to two days, weather permitting.

Planning, building control and Eccles

Two sets of rules matter in England. Planning: a rooflight on a house is normally permitted development if it projects no more than 0.15 m and stays below the highest part of the roof, but flats, listed buildings and Article 4 areas need checking. Building regulations: new openings need approval for the structure and energy performance, and a replacement is a controlled fitting. We are not registered with a competent person scheme, so we notify replacements to building control with a building notice and put the council's fee on the quote.

Help us quote accurately

What we cannot see, we have to guess, and guesses make quotes wider. So the more you send, the tighter the price. Useful: shots from the roof or garden, shots from the room underneath, a rough width and length, the roof finish, any access problems, and the product page if you have already ordered. Add the property postcode around M30 and we will come back with a quote or a survey date.

Common questions in Eccles

Does a rooflight need building regulations approval?

A new opening usually needs building regulations approval. A replacement is a controlled fitting: it must be self-certified by an installer registered with a competent person scheme or notified to building control. We are not registered with a scheme, so replacements we fit are notified to building control with a building notice, and the council's fee is shown on your quote.

Can you remove and dispose of the old rooflight?

Yes. Taking out the old unit is part of any replacement job, and it leaves with the rest of the waste unless you ask to keep it. Old domes, glass and frames go through proper waste routes. If removal turns up a rotten kerb or damaged decking, we show you what we have found and agree the repair with you before going any further.

What upstand height and roof pitch does roof lantern fitting need?

It depends on the product. Manufacturers usually specify a minimum upstand height above the finished roof surface, and a minimum pitch on the glass so rain runs off. We follow the maker's figures for your unit rather than a rule of thumb. If your existing kerb or roof falls short, we explain the options, such as raising the upstand or choosing a unit with built-in pitch.

For a free, no-obligation quote in Eccles, use the form or call us with the details of your roof.

Rear extension at dusk with lit rooflights and a roof lantern
Ready when you are

Roof lanterns in Eccles

Send photos and rough sizes, or ask for a survey for install work. One fixed written price before anything starts.

CallGet a quote