Fit-onlySupply & fitReplacementsTrade fitting
Fitting teams across England, Wales, Scotland & NI · Call 0800 088 6248
RooflightInstallers.co.uk
Borehamwood · WD6 · Hertfordshire

Roof lantern installation in Borehamwood

Our guide price for roof lantern installation starts from £3,095, and the real figure for your roof in Borehamwood depends on a handful of things: the size and type of roof lantern, whether the opening exists already, the roof covering, and how easy access is. We fix the price in a written quote before work begins. Nothing gets added on the day without your say-so. For a rough idea first, photos and a couple of measurements are enough to go on, and we cover all of Hertfordshire.

Guide price from £3,095 · Supply & fit

Guide prices in Borehamwood

About 1 × 2 m

£3,095 – £4,545including VAT at 20%

Aluminium lantern, double glazed, fitted and glazed on a ready upstand

About 1.5 × 3 m

£4,545 – £7,195including VAT at 20%

Mid-size lantern, solar-control glass options

2 × 4 m and over

£7,195 – £11,395including VAT at 20%

Large lanterns, lifting gear on the day

Guide ranges for supply & fit. Your price is fixed in a written quote after we have seen photos or surveyed. Scaffold, access towers or a crane are priced separately if the job needs them, and building control fees, where a job needs them, are shown as their own line.

Coverage in and around Borehamwood

Looking at a property near Borehamwood but not quite in it? We work across WD6, WD7 and WD23 and outwards to Barnet, Bushey and Wealdstone. Give us the full postcode when you get in touch, because access, parking and the route for a large unit all depend on the exact street. Those details shape the quote for any job around Borehamwood.

Your roof lanterns or ours

Your unit or ours, the fitting standard is the same. For supply and fit we choose a roof lantern to suit the roof and price it with the installation. For fit-only we work with what you have, after confirming it arrived undamaged, that it matches the builder's opening, and that the upstand will sit at the height the maker asks for. Report any transit damage to the seller, as the product cover is theirs and the maker's. Our written guarantee applies to the fitting itself.

On the day, we cover

  • Caps, end closures and ridge trims fitted and sealed
  • Roof membrane checked where it meets the lantern frame
  • Internal trims fitted to the ring beam or upstand
  • Following the build order — We assemble lanterns in exactly the sequence the instructions give.
  • Upstand size and tolerance — We check the kerb against the lantern maker's figures before the kit is opened.

Fitting your roof lantern, step by step

Protection comes before tools. Floors, furniture and stairs get covered, and the ceiling below the opening is sheeted to catch dust. Up top, the fitters confirm the opening is square and the upstand or flashing suits what the maker specifies. Fixing follows, then weather-sealing into the membrane, felt or tiles. Only once the roof is tight do they turn to the internal reveal. Time on site for a roof lantern: one to two days, weather permitting.

Do you need permission in Borehamwood?

England's rules in short: permitted development usually covers a rooflight on a house roof provided it doesn't stick out more than 0.15 m or rise above the ridge, though a listed building always needs consent and some streets have Article 4 directions. Building regulations apply to new openings, and replacements go through building control; as we are not registered with a competent person scheme, we use a building notice and show the fee on the quote. The energy limit for rooflights in existing homes is 2.2 W/m²K, and the 2026 Approved Document L, in force from 24 March 2027, keeps that figure.

Details that speed up your quote

Start with your phone. Take a picture of the roof where the unit goes or already sits, then one from inside looking up. Measure what you can, even roughly. Tell us what the roof is covered with and how a fitter would reach it: ladder, garden access or scaffold. Bought it already? Send the link or spec. Add your full postcode, for example in WD6, and we can price it.

Common questions in Borehamwood

Does a rooflight need building regulations approval?

A new opening usually needs building regulations approval. A replacement is a controlled fitting: it must be self-certified by an installer registered with a competent person scheme or notified to building control. We are not registered with a scheme, so replacements we fit are notified to building control with a building notice, and the council's fee is shown on your quote.

Can you replace an old dome without redoing the whole roof?

Usually, yes. If the existing kerb is sound, level and tall enough, a new unit can often sit on it with a fresh seal to the roof covering. If the kerb is rotten or too low, we rebuild it and patch the covering around it rather than stripping the whole roof. This is checked at the survey and included in the written quote, so you know the full scope first.

Do you make good inside after fitting?

Yes, where the quote includes it. Internal finishing usually means lining the reveal with plasterboard, taping or skimming, and fitting trim where it meets the ceiling. Some people prefer their own plasterer or decorator to finish off, which is fine. The written quote spells out exactly where our work stops, so nobody is left guessing about who does what once the unit is in.

Tell us your postcode, WD6 or close by, and what you want fitted. We will reply with the next steps and a quote.

Rear extension at dusk with lit rooflights and a roof lantern
Ready when you are

Roof lanterns in Borehamwood

Send photos and rough sizes, or ask for a survey for install work. One fixed written price before anything starts.

CallGet a quote